Teflon liner length

Start your own build thread so others can see how it's going, and even help out!
Post Reply
harley573
Printmaster!
Posts: 72
Joined: Mon Feb 25, 2013 10:53 pm

Teflon liner length

Post by harley573 »

Can anyone tell me how long the teflon liners are supposed to be? I can't find data on that anywhere.
User avatar
mhackney
ULTIMATE 3D JEDI
Posts: 5391
Joined: Mon Mar 26, 2012 4:15 pm
Location: MA, USA
Contact:

Re: Teflon liner length

Post by mhackney »

It depends on which version of the hot end and nozzle you have.

Sublime Layers - my blog on Musings and Experiments in 3D Printing Technology and Art

Start Here:
A Strategy for Successful (and Great) Prints

Strategies for Resolving Print Artifacts

The Eclectic Angler
harley573
Printmaster!
Posts: 72
Joined: Mon Feb 25, 2013 10:53 pm

Re: Teflon liner length

Post by harley573 »

The newest one.
User avatar
mhackney
ULTIMATE 3D JEDI
Posts: 5391
Joined: Mon Mar 26, 2012 4:15 pm
Location: MA, USA
Contact:

Re: Teflon liner length

Post by mhackney »

Inner tube is 47.4mm
Outer tube is 39.8mm

These are off the new hot end that came with my Add-A-Struder kit last week.

Sublime Layers - my blog on Musings and Experiments in 3D Printing Technology and Art

Start Here:
A Strategy for Successful (and Great) Prints

Strategies for Resolving Print Artifacts

The Eclectic Angler
harley573
Printmaster!
Posts: 72
Joined: Mon Feb 25, 2013 10:53 pm

Re: Teflon liner length

Post by harley573 »

Awesome. Thanks! I just got my Max a few weeks ago and melted the plastic insulator and the teflon tubing due to a thermistor issue before I ever got to try putting plastic through it.
User avatar
aehM_Key
Printmaster!
Posts: 200
Joined: Sun Nov 18, 2012 4:46 am
Location: Germany
Contact:

Re: Teflon liner length

Post by aehM_Key »

The lenght of the inner tube depends on of much you screw the PTC fitting in. I installed both tubes separately being few mm to long, screwed the nozzle in (with only a slight momentum), measured the distance and cut the tubes.
User avatar
mhackney
ULTIMATE 3D JEDI
Posts: 5391
Joined: Mon Mar 26, 2012 4:15 pm
Location: MA, USA
Contact:

Re: Teflon liner length

Post by mhackney »

Hmm, I simply took the tubes out of the brand new hot end I just received and measured them. The PTC fits fine also. Custom fitting the tubes may give a better fit though.

Sublime Layers - my blog on Musings and Experiments in 3D Printing Technology and Art

Start Here:
A Strategy for Successful (and Great) Prints

Strategies for Resolving Print Artifacts

The Eclectic Angler
harley573
Printmaster!
Posts: 72
Joined: Mon Feb 25, 2013 10:53 pm

Re: Teflon liner length

Post by harley573 »

I used the lengths provided by mhackney and they seemed to work. I installed the nozzle until the flat face contacted the face of the heater body, then took it all apart to see if it looked like anything was smooshed. No visible sign of damage, so I put it back together and ran a piece of filament into it. Of course it stopped when it got to the nozzle orifice, but fed easily up to that point, so I think the lengths he provided are accurate.